Demo project record · simulated

Jurong Liquid-Cooled Node

Jurong, Singapore · Straits Compute · Procurement
Campus / IT
20 / 16 MW
Target RFS
Q2 2028
Forecast
Q2 2028
Readiness
81%
Critical path
MV switchgear
Cooling architecture
Full DLC
End user
Straits Compute (own capacity) + undisclosed cloud tenant
Customer type
Regional cloud / inference operator
Workload / density
Inference + fine-tuning, 100 kW/rack full DLC
Offtake
60% self-use, 40% contracted colocation
Utility / grid
SP PowerGrid — 66 kV, allocation under IMDA DC-CFA
Substation installed
2 × 20 MVA (40 MVA installed)
EPC / main contractor
Kajima Overseas Asia (main contractor)
Location
Singapore
SOURCE Client project briefLEVEL A · Verified directLAST VERIFIED 2026-08-03VERY HIGH

Phased deployment

Phase 110 MWQ2 2028Procurement
Phase 210 MWQ4 2028Detailed design

Supplier packages (4)

SupplierEquipmentQtyMWFactoryAwardEnergizationStage
Arcline Power Systems22 kV switchgear line-ups, 2500 A2 line-ups20Houston, US2026-05-11Q2 2028IN PRODUCTIONOpen
Thermaflux Liquid Cooling2.5 MW L2L CDU + cold plates + QDs8 CDUs (N+1)16Taoyuan, TW2026-07-06Q2 2028IN PRODUCTIONOpen
Modulus Infrastructure5 MW integrated block, DLC + rear-door hybrid4 modules20Johor, MY2026-06-29Q2 2028AWARDEDOpen
Voltbank Energy Storage1.5 MW UPS modules, UL 9540A cells16 modules20Ulsan, KR2027-01-11Q2 2028TENDEROpen

KNOWN RELATIONSHIPS

LOCATED INJurong, SingaporeLOCATION
OFFICIALHIGH
OFFICIALHIGH
TENANT OF (inbound)Straits ComputeCOMPANY
OFFICIALHIGH
POWERED BYSP PowerGridUTILITY
OFFICIALHIGH
INSTALLED BYKajima Overseas AsiaGC / EPC
OFFICIALHIGH
SUPPLIED TO (inbound)Arcline Power SystemsCOMPANYMV switchgear — 22 kV switchgear line-ups, 2500 A (2 line-ups)
OFFICIALHIGH
SPECIFIED FORMV switchgearCATEGORY22 kV switchgear line-ups, 2500 A
OFFICIALHIGH
SUPPLIED TO (inbound)Thermaflux Liquid CoolingCOMPANYFull DLC liquid cooling — 2.5 MW L2L CDU + cold plates + QDs (8 CDUs (N+1))
OFFICIALHIGH
SPECIFIED FORFull DLC liquid coolingCATEGORY2.5 MW L2L CDU + cold plates + QDs
OFFICIALHIGH
SUPPLIED TO (inbound)Modulus InfrastructureCOMPANYPrefabricated power + cooling blocks — 5 MW integrated block, DLC + rear-door hybrid (4 modules)
REPORTEDLOW
SPECIFIED FORPrefabricated power + cooling blocksCATEGORY5 MW integrated block, DLC + rear-door hybrid
REPORTEDLOW
SPECIFIED FOR (inbound)Voltbank Energy StorageCOMPANYUPS / BESS ride-through — 1.5 MW UPS modules, UL 9540A cells (16 modules)
REPORTEDLOW
SPECIFIED FORUPS / BESS ride-throughCATEGORY1.5 MW UPS modules, UL 9540A cells
REPORTEDLOW

Every line states who, what and how we know it. Where a source names a company but not a model, the relationship stays at brand level rather than guessing a part number.

SCOPE COVERAGE — WHAT IS NOT KNOWN

4 of 7 scopes have a sourced supplier
POWERArcline Power Systems
COOLINGThermaflux Liquid Cooling
TCS / LIQUID LOOPThermaflux Liquid Cooling
MODULARModulus Infrastructure
MEPNot known
COMMISSIONINGNot known
NETWORKNot known
INTEL ACCELERATOR. All figures shown are demo data for structural demonstration. Nothing is presented as verified market intelligence.